DM serial high frequency electromagnetic flow meters are mainly used in high viscosity uniform medium such as detecting paper pulp, mud, cement slurry (containing fine particles), mortar, liquid that produces noise due to the physical reaction or electrochemical reaction or the medium affected by magnetic field around.
Recommended range of use: 0.5m/s10m/s continuous adjustable
Maximum range of use0.01m/s15m/s continuous adjustable
±0.5 measured value (standard), ±0.2% measured value (high accuracy)
≤1/2 of the measured value
- Minimum electrical conductivity
5μS/cm (deionized water 20μS/cm)
99% step change (equivalent to5τ)≥1s
High voltage AC 220VAC 50HZ
Low voltage DC 24VDC
Intermediate frequency, high frequency
(Include the sensor and transducer)AC power supply ≤10W
DC power supply ≤6W
- Ambient temperature (verification as Ex)
-20oC~+60oC
Bolt terminal, no bolt spring compaction wiring terminal
Cable interface M20X1.5 or 1/2'' NPT
IP67